FG6010 Duct Temperature and Humidity Transmitter with 0-10V Output

Measure air temperature and relative humidity and send the readings as analog voltage signals to compatible controllers or data acquisition equipment. FG6010 combines a flange-mounted probe with a 12–36V DC supply and selectable temperature measuring ranges.

  • Temperature and humidity voltage outputs for compatible analog input channels.
  • 0–10V output configuration, with 0–5V available on request.
  • Flange mounting for positioning the probe in a duct or air measuring location.
  • DIP-switch temperature range selection to match your measurement requirements.
0–10V
Analog voltage output
12–36V DC
Power supply
Flange
Duct mounting configuration

Specify the required output configuration when ordering. Match the receiving device's voltage input range and scaling to the transmitter settings.

Request a Quote

Include your required output, temperature range, quantity and delivery country.

Specifications & Flange Installation

Check the output configuration, supply voltage and measuring ranges against your receiving equipment and installation requirements.

FG6010 analog voltage output transmitter, flange-mounted configuration.
Specification FG6010
Measured parameters Air temperature and relative humidity
Output type Analog voltage signals for temperature and humidity
Output configuration 0–10V standard; 0–5V configuration available on request
Power supply 12–36V DC
Selectable temperature ranges
0 to 50°C — default −20 to 80°C −40 to 60°C −40 to 120°C
Temperature range selection DIP switches
Humidity measuring range 0–99.9% RH
Temperature accuracy ±0.5°C at 25°C
Humidity accuracy ±3% RH
Temperature resolution 0.1°C
Sampling interval 3 seconds
Standard cable length 1 m
Installation Flange mounting

Match the receiving device's input range and temperature scaling to the selected transmitter configuration. The DIP switches select the temperature measuring range; specify the required voltage output when ordering.

FG6010 technical drawing showing probe dimensions, mounting flange dimensions and product specifications
Open full-size drawing ↗

Probe & Mounting Flange

Check the probe and flange dimensions against your duct opening and available installation space.

Mounting
Flange-mounted probe
Sensing point
Probe tip exposed to the air being measured
Cable route
To the DC supply and compatible analog inputs

Position the sensing end in representative airflow. This probe measures air temperature and humidity; do not immerse it in water.

Connect the Signals and Match the Measuring Range

Use the wiring diagram to identify the supply and signal leads, then match the transmitter's temperature range to the receiving equipment.

FG6010 wire color identification and DIP switch diagrams for temperature range selection Open full-size wiring and switch diagram ↗
Refer to the diagram supplied with your unit for wire colors and DIP switch positions.
01 / Electrical Connections

Power, Temperature and Humidity Signals

FG6010 requires a 12–36V DC supply. Temperature and humidity are provided as separate analog voltage signals for compatible input channels.

Supply positive
Connect to the DC supply positive terminal.
Supply negative
Connect to the DC supply negative terminal; follow the receiving device's requirements for signal reference and common.
Temperature output
Connect to a compatible analog voltage input.
Humidity output
Connect to a separate compatible analog voltage input.
02 / Temperature Range

Set the Range and Configure Input Scaling

The DIP switches select the temperature measuring range. Use the switch positions shown in the diagram for your required range.

  1. Select the required temperature range before powering the installation.
  2. Confirm whether your transmitter is configured for 0–10V or 0–5V output.
  3. Set the receiving device's input range and temperature scaling to match.

Example: If the transmitter is set to 0–50°C, configure the temperature input for the same 0–50°C measuring range and the ordered voltage output.

Air Temperature and Humidity Signals for Your Equipment

Use FG6010 where air temperature and relative humidity need to be measured and supplied to compatible analog voltage inputs.

FG6010 duct temperature and humidity probe with a separate mounting flange and signal cable
Flange-mounted configuration for air measurement. Position the sensing end in representative airflow and protect it from direct water spray.
Duct Air Measurement

HVAC & Ventilation Ducts

Position the probe inside the duct to measure air temperature and relative humidity at the sensing point. Check the probe dimensions, insertion position and flange mounting space against your duct installation.

Equipment Integration

Air Handling & Ventilation Equipment

Supply temperature and humidity measurements to an equipment controller that accepts the ordered voltage output. Choose the temperature range to suit the air conditions being measured and configure the controller's input scaling to match.

Analog Voltage Inputs

PLCs & Data Acquisition Equipment

Connect the temperature and humidity outputs to separate compatible analog input channels. Confirm the accepted voltage range, signal reference and power supply before selecting the transmitter configuration.

Frequently Asked Questions

Answers about voltage outputs, controller compatibility, measuring ranges and flange installation.

Does FG6010 provide 0–10V or 0–5V output?

The standard configuration provides 0–10V analog voltage outputs for temperature and humidity. A 0–5V configuration is available on request. Specify the required output when ordering so it matches your receiving equipment.

The temperature range DIP switches are used to select the measuring range, not to select between these output configurations.

Can FG6010 connect to my PLC or controller?

It can connect to equipment with compatible analog voltage inputs. Reading both temperature and humidity requires separate input channels for the two signals. Check the accepted voltage range, signal reference and input scaling.

FG6010 needs a 12–36V DC supply. Send us the receiving device's model or input specifications if you need help checking the match.

How do I select the temperature measuring range?

Use the DIP switch positions shown in the wiring and range selection diagram . The available ranges are 0–50°C, −20–80°C, −40–60°C and −40–120°C, with 0–50°C as the default setting.

Configure the receiving device's temperature scaling to match the selected range and the ordered voltage output.

Can the probe measure water or other liquids?

FG6010 measures air temperature and relative humidity. The sensing probe should be exposed to the air being measured and must not be immersed in water or other liquids.

If the installation is exposed to condensation or direct spray, describe the conditions so we can check suitability before you order.

What mounting configuration is shown on this page?

This page shows the flange-mounted configuration. Check the probe dimensions, duct opening, insertion position and available flange mounting space against the installation drawing.

Position the sensing end in representative airflow and plan the cable route to the supply and receiving equipment.

Does FG6010 require an RS485 communication protocol?

FG6010 is the analog voltage output model. The receiving equipment reads the temperature and humidity voltage signals through its analog inputs. Setup involves matching the wiring, voltage input range and measurement scaling.

If your equipment requires an RS485 connection, include that requirement in your inquiry so we can help you select the appropriate model.

Request a Quote for FG6010

Need a flange-mounted temperature and humidity transmitter for your equipment? Send us your requirements so we can confirm the output configuration, measuring range, pricing and shipping options.

Include these details if available:

  • Output and power supply: Required 0–10V or 0–5V output, and your available DC supply voltage.
  • Measuring conditions: Expected air temperature and humidity, installation location and cable requirements.
  • Receiving equipment: The controller or PLC model, or its analog voltage input specifications.
  • Quantity and destination: How many FG6010 units you need and the delivery country.

Not sure which configuration you need? Describe your application and the equipment you want to connect. We can help check the product specifications and confirm suitable options with the supplier.