LX933 Dual Channel Temperature Display with Two Probes

View two temperatures together without checking two separate displays. LX933 connects to two external waterproof probes, allowing you to check two tanks, two locations, or water and nearby air temperature on one LED screen.

  • Upper and lower LED readings show the two temperature channels simultaneously.
  • Two external waterproof temperature probes for separate measuring points.
  • Each probe has a standard 5 m cable for flexible positioning.
  • Wall mounting or a rear support stand keeps the screen convenient to view.
2 Channels
Simultaneous temperature readings
2 Probes
External waterproof sensors
5 m Each
Standard probe cable length
Request a Quote

Tell us what each probe will measure, your required quantity and the delivery country.

Two Probes. Two Readings. One Screen.

Each probe supplies its own temperature reading. The upper and lower display rows let you view both measuring points together.

LX933 diagram identifying channel 1 on the upper display and channel 2 on the lower display
Each display channel corresponds to a separate external temperature probe.

Channel 1 — Upper Reading

Place the first probe at your first measuring point. Its temperature appears on the upper row of the LED screen.

Channel 2 — Lower Reading

Position the second probe at the other measuring point. Its temperature appears on the lower row, visible alongside the first reading.

Example: Water and Nearby Air Temperature

Place one probe at the water measuring point and the other in the nearby air. Both readings remain visible on one screen. You can also position the probes in two separate tanks or at two locations within the same area.

Close-up illustration of the LX933 external waterproof temperature probe

Two External Probes, Each with a 5 m Cable

Route each cable from its measuring point to the display. Keep the screen, power adapter and electrical connections dry and protected. For other cable lengths or specific measuring media, include your requirements in the inquiry.

Specifications & Installation

Check the two-channel configuration, probe cable lengths and installation layout before choosing your display position.

LX933 dual-channel temperature display specifications.
Specification LX933
Measured parameter Temperature at two measuring points
Temperature channels 2
Display Dual-row LED display with simultaneous temperature readings
Probe configuration 2 external waterproof temperature probes
Standard probe cables 5 m per probe
Temperature measuring range −40 to 120°C
Temperature accuracy ±0.5°C at 25°C
Display resolution 0.1°C
Power supply 5V DC via power adapter
Construction Aluminum-alloy housing with a tempered-glass front panel
Installation Wall mounting or rear support stand

Each probe measures at its own location. The measuring range applies to the probes, not the display unit's ambient operating conditions. Keep the display, adapter and electrical connections dry.

LX933 thermometer dimensional drawing showing the front display, rear mounting structure and side controls

Dimensions & Mounting Layout

Refer to the drawing for body dimensions, mounting positions and access to the controls.

Wall mount
Rear mounting points
Desktop
Rear support stand
Cable routing
Two probe cables and a power connection

Check both probe cable routes before mounting. Leave room for the side controls, connections and the support stand when in use.

View Two Measuring Points Together

Use the two probes for water and nearby air, separate tanks, or two room locations. Both temperatures remain visible on one screen.

Application illustrations for LX933 showing a swimming pool, sauna and hot tub
Pool, Sauna & Spa Applications
Illustration of LX933 displaying separate temperature readings for two sauna rooms
Two-Location Temperature Viewing

Application illustrations. Select probe locations, cable routes and a protected display position to suit the installation.

Water + Air

Swimming Pools & Spa Areas

Place one probe at the water measuring point and the other at a nearby air-temperature measuring point. Staff can view both readings during routine checks without moving between separate displays.

Tank 1 + Tank 2

Fish Tanks & Water Tanks

Position one probe in each tank and view the two temperatures together. Each probe has its own standard 5 m cable, allowing separate routes back to a shared display location.

Location 1 + Location 2

Two Rooms or Measurement Zones

Check temperatures at two room locations or two points within the same area. For sauna applications, tell us the expected heat and moisture conditions so we can confirm probe suitability. Keep the display and adapter in a dry, protected location.

Frequently Asked Questions

Answers about the two temperature channels, probe placement and installing your display.

What do the upper and lower readings represent?

Each reading corresponds to a separate external temperature probe. Channel 1 appears on the upper row, and Channel 2 on the lower row. You can view both temperatures simultaneously on one screen, with one probe at each measuring point.

Can one probe measure water and the other measure air?

Yes. You can position one probe at the water measuring point and the other in the nearby air. You can also use the two probes to check separate tanks or two locations within the same area. Keep the display and electrical connections dry.

For saltwater, chemically treated water or other potentially corrosive liquids, tell us the medium so we can confirm probe material suitability.

Is the cable 5 m long for each probe?

Yes. Each probe has its own standard 5 m cable. Check both cable routes from the measuring points to your planned display location. If you need different lengths, include the required length for each probe in your inquiry.

Can the display be installed in a wet area or inside a sauna?

The waterproof probes and the display have different installation requirements. Keep the display, power adapter and electrical connections dry and protected. A probe's measuring range does not establish the screen's resistance to heat, steam or water.

For sauna installations, describe the expected temperature, moisture conditions and proposed probe and display positions so we can confirm suitability before you order.

Does LX933 measure humidity as well as temperature?

LX933 measures two temperatures; the lower reading is another temperature channel, not relative humidity. If you need temperature and humidity readings, see the LX915 temperature and humidity meter .

How is LX933 mounted and powered?

LX933 supports wall mounting or placement using its rear support stand. It operates from a 5V DC power adapter. Allow space for both probe cables, the power connection and access to the side controls. Tell us your delivery country so we can confirm the adapter plug.

Request a Quote for LX933

Need to view two temperatures on one screen? Tell us about both measuring points so we can confirm the probe configuration, pricing and shipping options for your order.

Include these details in your message:

  • Measuring points 1 and 2: What each probe will measure, such as water and nearby air, or two separate tanks. Include the expected temperature ranges.
  • Probe cable lengths: Whether the standard 5 m cable per probe suits your installation, or the length needed for each probe.
  • Quantity and destination: How many LX933 units you need and the delivery country.

Need help checking the installation? Describe where you plan to place the two probes and the display. Include any exposure to heat, steam or splashes so we can check suitability before confirming your order.

This field is required.
This field is required.
This field is required.
This field is required.